Portable EV Charging BESS

Portable EV Charging BESS

For EV charging, home & light-commercial use

A 1–2 kW portable BESS (portable power station) is excellent for home and small commercial backup, site work, events, and slow / emergency EV charging (Level-1 / trickle charging or charging small electric scooters / 2-wheelers).

Get In Touch

Quick Overview

Portable Battery Energy Storage Systems (BESS) provide flexible, mobile power solutions for various applications. While they cannot fast-charge modern passenger EVs (which need several kW to 100s of kW for DCFC), they are perfect for many practical uses.

EV Charging Reality Check

Typical household single-phase charging (Level-1) provides ~1.2–3.3 kW depending on supply and on-board charger; that means a 1–2 kW BESS will only provide slow charging (adding only a few km of range per hour) for passenger EVs — useful for emergencies or overnight top-ups, not for regular fast charging.

Power & Inverter

  • Continuous AC output: 1,000 W or 2,000 W
  • Surge/peak capability: 2× continuous or more
  • Output waveform: Pure sine wave
  • AC output configurable to regional mains

Battery & Charging

  • Chemistry: LiFePO₄ (LFP) recommended
  • Usable capacity: 1-4 kWh options
  • Cycle life: >2,000–6,000 cycles for LFP
  • AC, solar, and car charging inputs

Key Applications

  • Emergency EV top-up / Level-1 charging
  • Home backup for essentials
  • Small commercial & pop-up stalls
  • Mobile work & events
  • Field service & telecommunications
  • Fleet support for low-power EVs / e-bikes
Safety Features

BMS with cell balancing

Active thermal management

Protection against over/under voltage

Typical Use Cases

Where 1–2 kW portable BESS excels in practical applications

Emergency EV Top-up

Level-1 charging for overnight trickle or range extension, best for small EVs, two-wheelers or plug-in hybrids.

1-2 kW Capacity
Home Backup

Power essentials: lights, Wi-Fi/router, laptops, fans, medical devices, small fridge for short durations.

1-2 kW Capacity
Small Commercial

POS systems, small office essentials, pop-up stalls, kiosks requiring portable power solutions.

2 kW Capacity
Mobile Work & Events

Power for projectors, cameras, PA systems, tablet/phone charging at remote locations or events.

1-2 kW Capacity
Field Service & Telecom

Keep critical communications equipment running during field operations or service outages.

2 kW Capacity
Fleet Support

Fast deployment, portable charging for low-power EVs, e-bikes, and electric two-wheelers.

1-2 kW Capacity

Detailed Specifications

Technical details for portable BESS systems

Power & Inverter
  • Continuous AC output: 1,000 W or 2,000 W (select model)
  • Surge/peak capability: 2× continuous or more for short bursts
  • Output waveform: Pure sine wave (mandatory for sensitive electronics)
  • AC output: Configurable to regional mains (e.g., 230 V / 50 Hz for India)
Battery System
  • Chemistry: LiFePO₄ (LFP) recommended (safety + cycle life)
  • Usable capacity: 1 kW unit → 1–2 kWh; 2 kW unit → 2–4 kWh
  • Depth of discharge (usable): Typically 90% of nominal capacity
  • Expected cycle life: >2,000–6,000 cycles for LFP with good BMS
Charging & Inputs
  • AC charge rate: ≥1,000 W (fast recharge from grid)
  • Solar input (MPPT): Optional 200–1,000 W depending on panel plan
  • Car/12V input: Optional for mobile charging
  • Recharge time: 1-4 hours depending on input source
EV Charging Interface
  • AC EVSE: Type-2 / J1772 / local standard for Level-1/2 charging
  • Optional integrated wallbox: With current limit configurable for safe EV connection
  • Important: For DC fast charging (50 kW+), a 1–2 kW BESS is NOT suitable
  • Fast charging alternative: Containerized mobile BESS + high-power PCS required

Technical Specifications

Detailed technical data for larger BESS systems

Battery System

  • Battery Chemistry: LFP (LiFePO₄)
  • Energy Capacity Options:
    • 1 MW system → 1–2 MWh battery
    • 2 MW system → 2–4 MWh battery
  • Cycle Life: 4,000–8,000 cycles
  • DC Voltage: 600–900 V DC (high-voltage stack)
  • Thermal Management: Liquid cooling (standard for >1MW systems)

Power Conversion System (PCS)

  • Rated Output Power: 1000 kW or 2000 kW
  • AC Output: 400/480 V, 3-phase
  • Bidirectional: Allows charging from grid & discharging to EV
  • Efficiency: 93–96%

EV Charging Module Configurations

Configuration Total Power Charging Standard Application
4 × 250 kW chargers 1 MW total CCS2 / GB/T / CHAdeMO High-traffic charging stations
10 × 200 kW chargers 2 MW total CCS2 / GB/T / CHAdeMO Fleet charging depots
20 × 100 kW chargers 2 MW total CCS2 / GB/T Public charging parks

Thermal, Safety & Controls

BMS: With cell balancing, CAN/Modbus telemetry

Active thermal management: Air cooling for small units; liquid cooling for higher continuous duty

Protection: Over/under voltage, overcurrent, short circuit

Safety: Fire detection, emergency stop functionality